INC-5

Musty smell and wet floor near bathroom

Medium New Water / plumbing

What happened

Floor tiles next to the bathroom wall are wet in the morning.

Timeline

  1. Reported by Resident, Apartment 3.

  2. Linked to alert ALT-1 by BuildingMind.

What the records show

BuildingMind linked it to alert ALT-1, "Possible water leak in Apartment 3": Water use in Apartment 3 on 24 Oct was 44.9% above expected. Night flow between 02:00 and 05:00 averaged 12.8 L/h where about 2.0 L/h is normal, which suggests continuous flow. Three damp or water reports came from Apartment 3, Apartment 1 directly below, and the floor 2 stairwell in the last 3 days. The link is possible, not confirmed.

Suggested next checks

  • Inspect the water pipes in the Apartment 3 bathroom wall and the floor 2 riser cupboard. Close the Apartment 3 supply overnight and compare the meter reading in the morning.
Based on these records

Possible links, not confirmed causes.