Building Systems
Interactive view of water and electrical infrastructure
Cold water
Hot water
Heating
Electrical power
Data & low voltage
Transparent walls
Equipment
Drag to rotate · Scroll to zoom · Right-click to pan
Important alerts
Active alerts whose problem showed up on 3 or more different days in the last 30 days.
Alerts
Warnings built from incidents, readings and repairs.
CriticalOpen
Possible water leak in Apartment 3
ALT-1 · 24 Oct, 06:10 · Floor 2, Apartment 3
Water use in Apartment 3 on 24 Oct was 44.9% above expected. Night flow between 02:00 and 05:00 averaged 12.8 L/h where about 2.0 L/h is normal, which suggests continuous flow. Three damp or water reports came from Apartment 3, Apartment 1 directly below, and the floor 2 stairwell in the last 3 days. The link is possible, not confirmed.
Why it was raised
- Difference from normal+45% Rule WATER_NIGHT_FLOW
- Linked reports3
- Meter readings3
Evidence connected
- Incident INC-4Damp ceiling in Apartment 1, directly below Apartment 3.22 Oct
- Incident INC-5Wet floor near the bathroom in Apartment 3.23 Oct
- Incident INC-6Water stain next to the floor 2 riser.23 Oct
- Meter readingApartment 3 water at 02:00: 12.99 L/h, expected about 2.0 L/h.24 Oct, 02:00
- Meter readingApartment 3 water at 03:00: 12.76 L/h, expected about 2.0 L/h.24 Oct, 03:00
- Meter readingApartment 3 water at 04:00: 12.74 L/h, expected about 2.0 L/h.24 Oct, 04:00
- ALT-1: Possible water leak in Apartment 3
What to check
- 1Inspect the water pipes in the Apartment 3 bathroom wall and the floor 2 riser cupboard. Close the Apartment 3 supply overnight and compare the meter reading in the morning.
A possible link, not a confirmed cause. A technician should verify on site.